PRODUCT DATA
Hand-held Building Acoustics Analyzer Types 2250 and 2270 with Building Acoustics
Software BZ-7228
Building Acoustics is the assessment of sound insulation in
buildings and building elements. It is important for the well-being of
people in their homes, workplace or public venues, thus minimum
standards are set in the building regulations of each country.
BZ-7228 software is available for Hand-held Analyzers Type 2250
and Type 2270. It provides the flexibility, ease of use and
confidence in your results that field measurements require in
building acoustics.
Type 2270 users can turn their analyzer into a 2-channel building
acoustics analyzer with 2-channel Option BZ-7229.
Back at the office, Qualifier Type 7830 and PULSE Reflex Building
Acoustics Type 8780 offers versatile post-processing and reporting
of your measurement results.
Uses and Features
Uses (BZ-7228)
Measurement of:
Airborne sound insulation
Façade sound insulation
Impact sound insulation
Features (BZ-7228)
Complete hand-held building acoustics analyzer
Measures source and receiving room level spectra
Built-in pink and white noise generator
Equalisation of sound source spectra
Parallel or serial measurements
Measures reverberation time spectra:
Impulse and Interrupted Noise methods
Built-in pink and white noise generator
Measurement position management
Calculates final results on the spot: ISO plus
12 national standards
Measurement quality indicators
Colour touch screen user interface
Signal recording, voice commentary and integrated camera
(Type 2270 only) to document test environment
Single-channel measurements (Type 2250 and 2270)
2-channel measurements (Type 2270 only, with BZ-7229)
Uses (Type 7830 or Type 8780)
Building acoustics calculation
Report generation
Data archiving
Features (Type 7830 or Type 8780)
Building acoustics results calculation
Analysis and report generation in one application
(Type 8780 incorporates Microsoft
®
Office)
Automatic data integrity checking
Before and after scenario combination and comparison in one
project (Type 8780 only)
ISO plus 12 national standards
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - PRODUCT DATA

PRODUCT DATAHand-held Building Acoustics Analyzer Types 2250 and 2270 with Building Acoustics Software BZ-7228Building Acoustics is the assessment of

Page 2 - The Hand-held Analyzers

10Fig. 15 Accessories for building acoustics measurementsAccredited Calibration Services at Brüel& KjærEnsure traceable measurement history from d

Page 3

11Specifications – Type 2250/2270MicrophoneSUPPLIED MICROPHONEType 4189: Prepolarized Free-field ½″ MicrophoneorType 4190: Free-field ½″ MicrophoneNom

Page 4 - Reverberation Time

1240°C charging time will be prolonged. With external charger ZG-0444 (optional accessory), typically 5 hoursNOTE: It is not recommended to charge the

Page 5 - Standards

13Linear Operating Range: In accordance with IEC 61672, A-weighted: 1kHz: Single Range: 24.8 to 140 dBHigh Range: 43.0 to 140 dBLow Range: 24.8 to 110

Page 6 - Wireless Systems

14Measurement Control Measurement Sequence: Supports measuring:• at all microphone positions before using another source• at a microphone position for

Page 7 - Reporting your Data

15Specifications – PULSE Reflex Building Acoustics Type 8780PULSE Reflex Building Acoustics is the software package for post-processing and reporting

Page 8 - Reporting Your Data

HEADQUARTERS: Brüel &Kjær Sound & Vibration Measurement A/S · DK-2850 Nærum · DenmarkTelephone: +45 7741 2000 · Fax: +45 4580 1405 · www.bksv.

Page 9 - Complete System

2The Hand-held AnalyzersFig. 1 Hand-held Analyzers Type 2250 and 2270 Types 2250 and 2270 are robust, hand-held anayzerplatforms designed to host a wi

Page 10 - Compliance with Standards

3The sound level depends on the position in the rooms, so several microphone positions are used to measurethe average of the source room level, L1, th

Page 11

4Press the Save pushbutton to save the measurement (see Fig. 5, right). You are now ready to measure atposition 2.Fig. 6 Left: Typical 2-channel inspe

Page 12 - Broadband Analysis

5Fig. 8 Reverberation time spectrum (left); reverberation decay curve (centre); andoverview of results (right)NOTE: A dedicated Reverberation Time Sof

Page 13

6Other TasksFaçade Sound InsulationFaçade sound insulation is a variant of airborne sound insulation, with its own standards. The “source room”is the

Page 14

7Fig. 11 Typical building acoustics project using Type 8780. Data are presented graphically and numerically with detailed data quality indications, us

Page 15

8Reviewing and Reporting using Qualifier Type 7830Fig. 14 Typical building acoustics project using Type 7830With Qualifier Type 7830, youcan view, rec

Page 16 - Service Products

9Table2 Calculated parametersComplete SystemBrüel & Kjær provides a wide range of accessories to help you build a complete building acousticsmeas