The sound level depends on the position in the rooms, so several microphone positions are used to measure
the average of the source room level, L1, the average of the receiving room level L2 and the average of the
background noise level B2. The average reverberation time T2 is also measured using several positions.
In Touch with your Measurements
The spectra required (L1, L2, etc.,) may be measured in any order, to suit field conditions and your
preferences. Fig. 4, Fig. 5 and Fig. 6 show typical displays when performing both single- and 2-channel
building acoustics measurements.
Fig. 4 shows a typical building acoustics display when you are ready to measure the first L2 position, with
source position 1.
Fig. 4
Typical single-channel
display when you are
ready to measure the
first L2 position, with
source position 1
The instantaneous (live) spectrum is shown and the high-resolution, colour, touch screen shows the setup,
status and data at a glance.
Using the stylus (or navigation pushbuttons) you can directly activate the indicated features (except those
with dashed lines in Fig. 4 above).
You can check the generator and loudspeaker signal level by tapping the Generator icon to switch the
generator on and off.
Fig. 5
Typical single-channel
display
Left: Inspection phase
Right: Save phase
Once the spectrum at position 1 has been measured (for the preset time of 10 s), you may inspect the
spectrum before saving (see Fig. 5, left).
A yellow ‘smiley’ icon indicates that you may be able to improve the measurement at one frequency band.
Tap the smiley icon to read the explanation and take the necessary action.
Standard
Function
Broadband Levels
Path
Spectrum
Task
Sound Field
Position
L
eq
Instant. Level
Clock
View Tabs
Menus
Parameter
Parameter
Y Scale
Cursor
Spectrum (Instant.)
Spectrum (L
eq
)
Elapsed Time
Measurement Status
Generator
Data saved
L2 (average)
Data not yet saved
Ready for Pos. 2